Local gas distribution and transmission companies utilize Electronic Pressure Recorders to monitor pressure in the Gas distribution and transmission grid. Electronic Pressure Recorders are a key element in the gas value chain, contributing to the security and availability of gas within the gas distribution network.

Honeywell’s ERX 350 Electronic Pressure Recorders are intended to simplify and optimize pressure monitoring applications. This new Pressure Recorder, based on the EC 350 electronic corrector platform offers best-in-class accuracy, expanded memory, advanced diagnostics and integrated cellular communications. The ERX 350 also reduces maintenance requirements and is intuitive and simple to use.

ERX 350 Electronic Pressure Recorder Specifications

Technical data
Value
Maximum error over the full temperature range -40° to 70°C (-40 to 170°F) including linearity, repeatability and hysteresis
Pressure: ±0.1% of full scale
Temperature: ±0.1% of reading
Maximum error at reference conditions
Pressure: ±0.04% of full scale
Temperature: ±0.1% of reading
Long Term Drift
Pressure: ±0.4% of full scale over 10 years
Recommended Calibration Time
10 years
Environmental Conditions
Ambient temperature range: -40 to 77°C (-40° to 170°F)
Ambient humidity: 0 to 95% non-condensing
Power Supply Options
Alkaline receptacle (5-7 years)
Lithium batteries (10 years)
DC power
Certifications
CSA C/US Class I, Div 2, Groups C&D
CSA C/US Class I, Div 1, Groups C&D
IEC-Ex Ex ia IIB T4